Technical Data
Model |
L3H16R1 |
Max.speed |
16000rpm |
Max.rcf |
17800×g |
Speed accuracy |
±20rpm |
Temp control |
-20℃~+40℃ |
Temp accuracy |
±2℃ |
Timer range |
0~99min |
Noise |
<58db |
Display |
TFT |
Acceleration / Deceleration rates |
1-- 10 |
Power |
AC220V, 50/60Hz, 20A |
Weight |
40kg |
Dimension |
545x340x275(LxWxH) |
Rotor List
Order No. |
Description |
Max.Speed |
Max.rcf |
Material |
Tube Order No. |
|
Angle rotor |
0112005/16 |
12×0.5ml |
16000rpm |
17800×g |
Aluminium alloy |
P0001 |
0112015/16 |
12×1.5ml |
16000rpm |
17800×g |
P0002 |
||
0112022/16 |
12×2.2ml |
16000rpm |
17800×g |
P0003 |
||
01105/16 |
10×5ml |
16000rpm |
17800×g |
P0004 |
||
0124015/13 |
24×1.5ml |
13000rpm |
15710×g |
P0002 |
||
0124022/13 |
24×2.2ml |
13000rpm |
15710×g |
P0003 |
Description:
L3H16R1 micro centrifuge can be equipped with 3 kinds of rotors in the bench top version, offering a complete solution in the preparation of samples to be centrifuged for research labs, clinics, biotechnology, industry and hospitals.
The small in size, a software allows the operator to control the centrifugation parameters easily, and the graphics shown on the TFT touch colorful screen provide the user with an easy-to-handle machine and an ally in the daily tasks.
L3H16R1 allows you to control the rates of acceleration & deceleration from 1~10 profiles, you can quickly recall up to 30 daily-use programmable operation with RCF value calculated automatically.
Features:
◆Induction motor maintenance free.
◆Controlled by microprocessor
◆Minimum acceleration time.
◆Noise level lower than 60 dB.
◆Lid open programmable: automatically open at the end of the run or pressing the lid button.
◆RPM/RCF adjustable along the run.
Use friendly
◆TFT touch screen colorful.
◆RPM regulation on steps of 100, time from 1 to 99 minutes
◆Up to 30 programs on store.
◆Countdown starts at set RPM /RCF, allowing reproducible results.
◆Screen shows the values or graphics of set and updated.
◆Switches for open the lid, start, stop
◆Messages on screen indicating the state of centrifuge and accessories.
◆Lid latch motorized.
◆Rotors information in memory.
◆Touch selection directly.
Safety
◆Initial checking of the device and its accessories.
◆Stainless steel chamber with additional inner guard ring.
◆Lid dropping protection
◆Imbalance cut off.
◆Double manual emergency lid release.
◆It can not run with the lid open, neither open the lid when rotor runs.
◆Temperature probe inside the chamber of centrifugation, refrigerant R134A (libre CFC)