★ Testing items can be set randomly, auto check for substrate-off, auto retest, auto record sample and reagent blank, prozone testing available
★ Real-time display the reaction tray temperature and lamp status
★ RS232 standard interface, hospital data-system connecting and remote printing available
★ Probe performance: Liquid level detection, all-round anti-collision protection and inventory checking, have automatic stop and alarm prompt for an obstacle; special cleaning solution to prevent cross-contamination.
★ Probe cleaning: Automatic washing for both interior and exterior
★ Constant 300 tests/hour, up to 420 tests/hour
Reagent Tray
• 80 reagent positions
• Advanced reagent tray refrigeration system, Temperature: 2-10°C
• Reagent Bottle: Bottles with 15ml, 20ml, 30ml, 50ml, 70ml capacity are available
• Support single/double reagents; Reagents open system
Sample Tray
• 80 sample positions
• Compatible with disposable blood collection tube, micro cup and plastic tube
• Automatically identify the original sample tube and micro sample cup
• Random access, test according to the sample sequence, insert emergency at any time
• Real-time display sample testing status
Reagent Adding System
• Reagent probe has the liquid level detection, pre-heating and anti-collision protection functions.
• Reagent Volume: 20-500μl, 1μl by step
• Reagent probe will be cleaned before and after sampling to reduce the contamination
• Real-time reagent volume remaining
• Reagent volume tracking technology
Washing System
• 5 groups probes for washing cuvettes automatically
• 12 steps cleaning, lower cross contamination
• Optional acid- alkali cleanser
Sample Adding System
• Sample probe has the liquid level detection and anti-collision protection function
• Sample Volume: 2-100μl, 0.1μl by step
• Sample probe will be cleaned before and after sampling to reduce the contamination
• Sample probe blocking self-test alarm function
• Automatic dilution and re-measuring function
• Sample volume consumption tracking technology
Mixer System
• Independent mixer system, no hanging liquid
• Mixer probe will be cleaned before and after mixing to prevent cross contamination
• Mixer probe has the anti-collision protection function
Technical Specifications
Performance
Type: Discrete Automatic, Random Access
Principle: Absorption Spectrometry, Turbidimetry
Throughput: Constant 300tests/hour (without ISE)
Test Method: End-point, Fixed-time(two point), kinetic, support double reagent and double wavelength
Test Sequence: Run tests in strict accordance with sample sequence,
Insert emergency at any time
Optical System
Light Source: Halogen-tungsten lamp, 12V/20W, More than 2000hrs service time
Spectrometric Method: After spectrometric method
Wavelength: 8 -12wavelengths, selectable among 340-900nm
Absorption Range: 0-4.0Abs
Optical System: Integrated full closed optical system
Reaction System
Reaction Tray: 81 positions, cuvettes reusable
Reaction Volume: Mini 150μl
Reaction Tray: 80 positions, open system, independent tray
Reagent Volume: 20-500μl, 1μl by step
Reagent open system, close system for option
Temperature Control System
Refrigeration System: water -medium uniform cooling technology
Heating Time: less than 3minutes
Reagent Tray Temperature: 2-10°C
Reaction Temperature: 37±0.1°C
Temperature Fluctuation: ± 0.1°C
Refrigeration system: 24 hours cooling for reagent tray, temperature 2-10°C
Calibration and QC
Calibration Mode: Linear, Logit-4p, Logit-5p, Spline, Factor, Polynomial
Automatically check calibration curve and fitting the best calibration curve
QC Type: Multi-type
QC Rules: Multi-rule; default: Westguard
Status Monitoring: Real -time monitor the sample tray, reagent tray, reaction tray;
Real-time display reaction temperature, reagent remain, reaction curve,calibration curve and QC chart.
Inspection &Judgment: Reaction end point judgment, reaction linear range judgment, substrate depletion judgment, reagent blank absorbance judgment
Operation and Print
Operation System: Windows XP or Windows 7 Home
Database: SQL Server
Data Storage: Automatic storage and backup, permanently preserve all kinds of data
Print Content: Print content can be customized
Print Format: Provide a variety of print format
Working Conditions
Water Consumption: less than 10L/hour
Power Supply: AC 220 ±22V 50HZ ±1HZ
Power: Max 550VA
Ambient Temperature: 15°C-30°C
Dimension(L*W*H): 92x73x113cm
Net Weight: 120Kg